简体中文 English Latest News Contact Us
VIPER XL Advanced Model (Microcomputer Time/Stroke Control)
94625e5a58cfb759b7b46236d01d4a65_202112051139587a540c.jpg

Feature

Value

Power Requirements

190 - 265 VAC / 50 - 60 Hz Single Phase

size

H 280 x W 125 x D 420 mm

weight

20kHz 1000W & 2000W: 7.5 kg20kHz 2000W & 3000W: 8.0 kg35kHz 600W & 900W:  7.5 kg

Electric box color

RAL3020

Display screen

4 lines x 20 characters LCD screen, backlit

LED Light Bar

20 LED lights to show the peak welding output

LED

4 LED lights to display the status of the power box

keyboard

25 buttons (including ON/OFF)

Micro generator

16-bit / 20MHz

microprocessor

16-bit / 20MHz

Analog/digital signal converter

12-bit

Normal frequency range

20kHz: 19700 - 20150 Hz35kHz: 34700 - 35150 Hz

Power Measurement

Real Time

Frequency measurement

Instant Real Time, the generator can automatically adjust to the normal frequency range

Power loss measurement

Before welding, after welding, turn off this function

Rated output

20kHz: 1000 / 1500 / 2000 / 3000W35kHz: 600 / 900W

Maximum output

10% more than rated output

Internal Amplitude

Adjustable, range 60 - 100%, unit 5%

External Amplitude

Adjustable, range 60 - 100%, unit 5%

Operation Mode

Time, energy, ultrasonic stop, power, travel mode

Time setting range

0.005 - 9.999 s, precision 0.001 s

Energy setting range

0 - 99999.99 Ws, precision 0.01 Ws

Ultrasonic stop mode

Built-in

Power Range

0 - 100%

Stroke setting range

0 - 500.00 mm, error range 0.01mm

Counters and defective product counters

Range 0 - 999999999

Limit value mode

The required energy, time, power, stroke and number of workpieces can be set

Trigger Oscillation Mode

Time trigger setting range: 0.000 - 9.999 s Pressure trigger setting range: 0 - 6.5 bar / sensor 4 - 20 mA

Power output analog signal

Adjustable range 0 - 5 V

Travel deceleration

Adjustable range 0 - 500.00 mm

Press controller

Two-hand start switch & press air pressure

Internal power supply

24VDC/400mA, including voltage regulation and short circuit protection

Signal input

Opto coupler 20 - 28 V DC / max. 7 mA

Signal output

Opto coupler 22 - 26 V DC / 250mA, short circuit proof

Emergency Stop

Screen display message

Error Message

Screen Display / Hardware Output

PLC communication interface

Digital I/O Signal

Database

99 sets of memory

Software Updates

Through the BDE interface

buzzer

A sound will be emitted when the confirmation key is pressed and error messages appear

Connection plug

All D-sub

Pin Password

4-digit lock code to prevent the electric box parameter settings from being modified at will

Main power switch

Back of the electric box

language

English, German, Spanish, French, Italian, etc.

Service/Test Program

Hardware testing of all I/O points

Place the space at the right temperature

Operating temperature -5℃ ~ 45℃ / Storage temperature -20℃ ~ 60℃

Design and manufacturing location

Switzerland

Contact Us Sales outlets

友情链接: 灵科超声波 灵高超声波 声峰超声波

COPYRIGHT © 2020 by apsonic China 粤ICP备13004144号